Abstract

The increase in solar panel surface temperature reduces its efficiency,
becoming one of the main challenges in the utilization of solar energy. One
approach to utilize the waste heat is by integrating a Thermoelectric Generator
(TEG) into a Photovoltaic–Thermoelectric Generator (PV–TEG) Hybrid system.
This study aims to analyze the effect of thermal conductor layer variations on the
performance of a PV–TEG Hybrid system using a 100 Wp monocrystalline solar
panel equipped with 12 TEG modules. The thermal conductor layer variations
tested were without a conductor layer, copper plate, and thermal pad. The results
showed that the series configuration produced the highest output power of 0.02398
W and was subsequently used in the thermal conductor layer variation tests. The
configuration without a conductor layer produced the highest average output
power of 0.00959 W, followed by the thermal pad at 0.00639 W and the copper
plate at 0.00535 W. Furthermore, the PV–TEG Hybrid system improved the overall
efficiency by 0.0007–0.0026%, with the highest efficiency improvement achieved by
the configuration without a conductor layer.
Keywords: Photovoltaic; Thermoelectric Generator; PV–TEG; Copper Plate;
Thermal Pad; Energy Efficiency