Abstract

The increase in greenhouse gas emissions due to industrialization is driving
the energy transition toward renewable sources, one of which is solar energy
through bifacial photovoltaic (PV) technology, which is capable of absorbing
radiation from both sides of the module. This study analyzes and compares the
technical performance and techno-economic feasibility of bifacial PV systems
installed over water and sand channels under tropical climatic conditions. Testing
was conducted over one month (April 2026) using two half-cut cell bifacial PV
modules with a capacity of 670 Wp at the Energy Conversion and Conservation
Research Center Building, KST BJ. Habibie, Serpong. The measured parameters
included power, energy, efficiency, Performance Ratio (PR), Capacity Factor (CF),
the effects of wind speed and rainfall, as well as a techno-economic analysis using
the LCOE, NPV, BCR, and Payback Period indicators, with a discount rate of
4.75% and an operational lifespan of 25 years. The results show that the water
canal system generated 59.25 kWh of energy with a PR of 61.96%, a CF of 12%,
and an efficiency of 13.4%, outperforming the sand system, which only achieved
50.14 kWh, a PR of 52.4%, a CF of 10%, and an efficiency of 11.1%. This advantage
is driven by the natural cooling effect of water, which lowers the modules’ operating
temperature, whereas sand causes heat trapping up to 48.17°C. Rainfall was found
to reduce power output in both systems, while wind speed provided more effective
passive cooling in the water canal system. From an economic perspective, the water
canal system yielded an LCOE of Rp 1.294/kWh (below the PLN tariff), a positive
NPV of Rp 1.129.101, a BCR of 1,10, and a PBP of 14 years,8 months, whereas the
sand system produced an LCOE of Rp 1.509/kWh, a negative NPV, a BCR of 0,96,
and a PBP of 17 years, 7 months. The bifacial PV system above the water canal
proved to be technically and economically superior as a strategic recommendation
for solar energy development in tropical climates.
Keywords : bifacial PV, water canal, sand, performance ratio, techno-economic,
tropical climate